7.8.4.69 Pset_ElementAssemblyTypeTurnoutPanel
7.8.4.69.1 Semantic definition
Turnout panel properties used in railway. The property set can be used by the predefined type TURNOUT_PANEL of IfcElementAssembly.
7.8.4.69.2 Applicable entities
- IfcElementAssembly/TURNOUTPANEL
 - IfcElementAssemblyType/TURNOUTPANEL
 
7.8.4.69.3 Properties
| Name | Property Type | Data Type | Description | |
|---|---|---|---|---|
| IsAccessibleByVehicle | IfcPropertySingleValue | IfcBoolean | 
 Indicates whether the element is accessible by a vehicle or not.  | 
|
| BranchLineDirection | IfcPropertyEnumeratedValue | PEnum_BranchLineDirection | 
 Describes the direction associated to the branch line of the turnout (deviated branch).  | 
|
| TrackExpansion | IfcPropertyBoundedValue | IfcPositiveLengthMeasure | 
 In curvature context, bounded value of the expansion distance that can be added to rail gauge.  | 
|
| TurnoutCurvedRadius | IfcPropertySingleValue | IfcLengthMeasure | 
 If turnout is curved, the main branch radius of curvature.  | 
|
| TypeOfCurvedTurnout | IfcPropertyEnumeratedValue | PEnum_TypeOfCurvedTurnout | 
 Turnouts that are positioned in the curved part of the alignment.  | 
|
| InstallationPlan | IfcPropertyReferenceValue | IfcDocumentReference | 
 Reference to external information source about installation or construction plan of the element.  | 
|
| IsSharedTurnout | IfcPropertySingleValue | IfcBoolean | 
 Indicates if the turnout makes a connection to another infrastructure owner (for sharing costs).  | 
|
| MaximumSpeedLimitOfDivergingLine | IfcPropertySingleValue | IfcLinearVelocityMeasure | 
 Maximum speed for diverging line that corresponds to the type of turnout and design constraints.  | 
|
| TypeOfDrivingDevice | IfcPropertyEnumeratedValue | PEnum_TypeOfDrivingDevice | 
 Type of the driving device used for the turnout.  | 
|
| TrackElementOrientation | IfcPropertyEnumeratedValue | PEnum_TurnoutPanelOrientation | 
 Turnout panels can be placed in 2 mirror-symmetric directions in the field. To distinguish both ends of the turnout panel, a definition of an orientation system with respect to the panel is necessary. The orientation defines, if the panel is oriented in a way or opposite with respect to the direction of the alignment/stationing.  | 
|
| PercentShared | IfcPropertySingleValue | IfcPositiveRatioMeasure | 
 Percent of costs paid by the other infrastructure owner.  | 
|
| TrackGaugeLength | IfcPropertySingleValue | IfcPositiveLengthMeasure | 
 Basic track gauge of permanent way.  | 
|
| TurnoutPointMachineCount | IfcPropertySingleValue | IfcCountMeasure | 
 Count of point machines inside turnout panel.  | 
|
| TurnoutHeaterType | IfcPropertyEnumeratedValue | PEnum_TurnoutHeaterType | 
 Defines the kind of turnout heater installed.  | 
|
| TypeOfJunction | IfcPropertyEnumeratedValue | PEnum_TypeOfJunction | 
 The turnout part of the continuous welded rail.  | 
|
| TypeOfTurnout | IfcPropertyEnumeratedValue | PEnum_TypeOfTurnout | 
 Type of turnout.  |