7.11.4.1 Pset_ConcreteElementGeneral
7.11.4.1.1 Semantic definition
General properties common to different types of concrete elements, including reinforced concrete elements. The property set can be used by a number of subtypes of IfcBuiltElement, indicated that such element is designed or constructed using a concrete construction method.
7.11.4.1.2 Applicable entities
- IfcBeam
 - IfcBuildingElementProxy
 - IfcChimney
 - IfcCivilElement
 - IfcColumn
 - IfcFooting
 - IfcMember
 - IfcPile
 - IfcPlate
 - IfcRailing
 - IfcRampFlight
 - IfcRamp
 - IfcRoof
 - IfcSlab
 - IfcStairFlight
 - IfcStair
 - IfcWall
 - IfcBeamType
 - IfcBuildingElementProxyType
 - IfcChimneyType
 - IfcCivilElementType
 - IfcColumnType
 - IfcFootingType
 - IfcMemberType
 - IfcPileType
 - IfcPlateType
 - IfcRailingType
 - IfcRampFlightType
 - IfcRampType
 - IfcRoofType
 - IfcSlabType
 - IfcStairFlightType
 - IfcStairType
 - IfcWallType
 
7.11.4.1.3 Properties
| Name | Property Type | Data Type | Description | |
|---|---|---|---|---|
| AssemblyPlace | IfcPropertyEnumeratedValue | PEnum_AssemblyPlace | 
 Enumeration defining where the assembly is intended to take place, either in a factory, other offsite location or on the building site.  | 
|
| CastingMethod | IfcPropertyEnumeratedValue | PEnum_ConcreteCastingMethod | 
 The method of casting the concrete into its designed form.  | 
|
| StructuralClass | IfcPropertySingleValue | IfcLabel | 
 The structural class defined for the concrete structure (e.g. '1').  | 
|
| StrengthClass | IfcPropertySingleValue | IfcLabel | 
 Classification of the concrete strength in accordance with the concrete design code which is applied in the project.  | 
|
| ExposureClass | IfcPropertySingleValue | IfcLabel | 
 Classification of exposure to environmental conditions, usually specified in accordance with the concrete design code which is applied in the project.  | 
|
| ReinforcementVolumeRatio | IfcPropertySingleValue | IfcMassDensityMeasure | 
 The required ratio of the effective mass of the reinforcement to the effective volume of the concrete of a reinforced concrete structural element.  | 
|
| ReinforcementAreaRatio | IfcPropertySingleValue | IfcAreaDensityMeasure | 
 The required ratio of the effective area of the reinforcement to the effective area of the concrete At any section of a reinforced concrete structural element.  | 
|
| DimensionalAccuracyClass | IfcPropertySingleValue | IfcLabel | 
 Classification designation of the dimensional accuracy requirement according to local standards.  | 
|
| ConstructionToleranceClass | IfcPropertySingleValue | IfcLabel | 
 Classification designation of the on-site construction tolerances according to local standards.  | 
|
| ConcreteCover | IfcPropertySingleValue | IfcPositiveLengthMeasure | 
 The protective concrete cover at the reinforcing bars according to local building regulations.  | 
|
| ConcreteCoverAtMainBars | IfcPropertySingleValue | IfcPositiveLengthMeasure | 
 The protective concrete cover at the main reinforcing bars according to local building regulations.  | 
|
| ConcreteCoverAtLinks | IfcPropertySingleValue | IfcPositiveLengthMeasure | 
 The protective concrete cover at the reinforcement links according to local building regulations.  | 
|
| ReinforcementStrengthClass | IfcPropertySingleValue | IfcLabel | 
 Classification of the reinforcement strength in accordance with the concrete design code which is applied in the project. The reinforcing strength class often combines strength and ductility.  |