7.8.4.8 Pset_CableCarrierSegmentTypeDropper
7.8.4.8.1 Semantic definition
Properties that are applicable to a type or an occurrence of dropper.
7.8.4.8.2 Applicable entities
- IfcCableCarrierSegment/DROPPER
 - IfcCableCarrierSegmentType/DROPPER
 
7.8.4.8.3 Properties
| Name | Property Type | Data Type | Description | |
|---|---|---|---|---|
| CurrentCarryingCapacity | IfcPropertySingleValue | IfcElectricCurrentMeasure | 
 Maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value. Based on IEC60826-11-13. NOTE: The temperature specified value is maximum Design Ambient Temperature.  | 
|
| TensileStrength | IfcPropertySingleValue | IfcPressureMeasure | 
 Indicates the ability to withstand breakage apart under applied force.  | 
|
| AssemblyInstruction | IfcPropertyReferenceValue | IfcExternalReference | 
 Instructions to describe how the system / equipment / facility is assembled.  | 
|
| IsRigid | IfcPropertySingleValue | IfcBoolean | 
 Indication of whether the conduit is rigid (= TRUE) or flexible (= FALSE).  | 
|
| UltimateTensileStrength | IfcPropertySingleValue | IfcForceMeasure | 
 Indicates the maximum stress that a material or element can withstand before breaking while being stretched or pulled.  | 
|
| IsAdjustable | IfcPropertySingleValue | IfcBoolean | 
 Indicates whether the element is adjustable or not.  | 
|
| IsCurrentCarrying | IfcPropertySingleValue | IfcBoolean | 
 To indicate whether the current will go through the dropper.  | 
|
| NominalLoad | IfcPropertySingleValue | IfcForceMeasure | 
 The nominal load that a component can support.  |